Filter is necessary if the liquid is not clean (No solid contains)
■ High accuracy, ±0.2%, ±0.5%, ±1.0%;
■ Small, compact and lightweight, easy install and maintenance, wide range;
Operating Principle
Fluid entering the meter first passes through an inlet flow straightener that reduces its turbulent flow pattern. Fluid then passes through the turbine, causing the turbine to rotate at a speed proportional to fluid velocity. As each turbine blade passes through the magnetic field generated by the meter's magnetic pickup, an AC voltage pulse is generated. These pulses provide an output frequency that is proportional to volumetric flow.
Technical Data
Output: Pulse/4-20mA;
Accuracy:±1.0 of Rate/±0.5% of Rate;
Operating Temp.:-20...+60°C;
Fluid Temp.: -20...+150°C;
Housing Material: SS304/SS316;
Rotor Material: 2Cr13/CD4MCu;
Bearing Material: Tungsten Carbide.
Flow Range
Diameter (mm) |
Standard Range (m3/h) |
Extended Range (m3/h) |
4 |
0.04~0.25 |
0.04~0.4 |
6 |
0.1~0.6 |
0.06~0.6 |
10 |
0.2~1.2 |
0.15~1.5 |
15 |
0.6~6 |
0.4~8 |
20 |
0.8~8 |
0.45~9 |
25 |
1~10 |
0.5~10 |
32 |
1.5~15 |
0.8~15 |
40 |
2~20 |
1~20 |
50 |
4~40 |
2~40 |
65 |
7~70 |
4~70 |
80 |
10~100 |
5~100 |
100 |
20~200 |
10~200 |
125 |
25~250 |
13~250 |
150 |
30~300 |
15~300 |
200 |
80~800 |
40~800 |
Model Selection
Model | LWGY | Description | ||||||||
Diameter | XXX | DN4-DN200 | ||||||||
Converter Type | N1 | 24V DC; Pulse output; No display | ||||||||
N2 | 24V DC; Pulse output;No display; Ex | |||||||||
A | 24V DC; 4-20 mA output; Nodisplay; Ex | |||||||||
E1 | Battery power supply; No output; Ex; Digital Display | |||||||||
E2 | 24V DC; 2-wire 4-20mA output;Ex; Digital Display | |||||||||
E3 | 24V DC; Pulse output; Ex;Display | |||||||||
E4 | 24V DC; 0-20mA output; EX; Digital display | |||||||||
E5 | 24V DC; 3-wire 4-20mA / Pulse output; EX; Digital display | |||||||||
M | 220Vac; 4-20mA output; EX; Digital display | |||||||||
FE | FE:Fluidwell E series converter | |||||||||
FF | FF:Fluidwell F series converter | |||||||||
Notice: | 1)Modbus RS485 is optional for E2,E3,E4,E5 and M type | |||||||||
2)Dual Power(24VDC+Battery) is optional for E2,E3,E4,E5,M | ||||||||||
Accuracy | 10 | ±1.0% of Rate | ||||||||
05 | ±0.5% of Rate | |||||||||
02 | ±0.2% of Rate | |||||||||
Flow Range | S | Standard Range | ||||||||
E | Extended Range | |||||||||
Body Material | S4 | SS304 | ||||||||
S6 | SS316 | |||||||||
PL | Plastic (DN15-DN50) | |||||||||
Rotor Material | Cr | 2Cr13 | ||||||||
CD | CD4MCu | |||||||||
Explosion Proof | BT | Exd II BT6 | ||||||||
NA | No explosion proof | |||||||||
Connection | THM | Male thread; Available from DN4 … DN50 | ||||||||
THF | Female thread; Available from DN4 … DN50 | |||||||||
WAF | Wafer connection | |||||||||
DXX | D16: DIN PN16 flange;D25: DIN PN25… | |||||||||
AXX | A15: ANSI 150# flange;A30: ANSI 300#... | |||||||||
JXX | J10: JIS 10K flange;J20: JIS 20K… | |||||||||
Temperature | T1 | -20...+80 °C | ||||||||
T2 | -20...+120 °C | |||||||||
T3 | -20...+150 °C |